|
Professor of Biomedical Engineering
Deputy Director of the BMES ERC Neural prosthetics, neurophysiology and computer modeling of sensory-motor control systems.
Office: DRB B10
Phone: (213) 821-5311
Fax: (213) 821-3897
Email: mailto:gloeb@usc.edu
MDDE Webpage
BMES ERC Webpage
|
 |
|
Selected Publications
Misc. Medical Devices
Kaliki, R.R., Davoodi, R. and Loeb, G.E. Prediction of Distal Arm Posture in 3-D Space from Shoulder Movements for Control of Upper Limb Prostheses. Proceedings of the IEEE, 96(7):1217-1225, 2008.
Zou, Q. Tan, W., Kim, E.S., and Loeb, G.E. Single- and Triaxis Piezoelectric-Bimorph Accelerometers. J. of Microelectromechanical Systems, 17(1):45-57, 2008.
Loeb, G.E. and Wills, J. General-Purpose Technology for a General-Purpose Nervous System. ISCAS Conference 2008.
Loeb, G.E., Singh, J., Allen, J.G., Raphael, G., Buckley P., Blanco, C., Richmond, F.J.R. and Salter, G.D.V. A Document Navigation System for the Paperwork Jungle, MD&DI, p. 110-119, August 2006. http://www.devicelink.com/mddi/archive/06/08/008.html
Wolpaw, J.R., Loeb, G.E., Allison, B.Z., Donchin, E., do Nascimento, O.F., Heetderks, W.J., Nijboer, F., Shain, W.G. and Turner, J.N. BCI Meeting 2005-- Workshop on Signals and Recording Methods. IEEE Trans Neural Syst Rehabil Eng, 14(2):138-41, 2006.
Loeb, G.E. and Richmond, F.J.R. FES or TES: How to start an industry? Proceedings of the 4th Annual conference of the International Functional Electrical Stimulation society, Sendai, Japan, 169-172, 1999.
Bak, M., Girvin, J.P., Hambrecht, F.T., Kufta, C.V., Loeb, G.E. and Schmidt, E.M. Visual sensations produced by intracortical microstimulation of the human occipital cortex. Med. & Biol. Engng and Comput. 28:257-259, 1990.
Loeb, G.E., McHardy, J., Kelliher, E.M. and Brummer S.B. Neural Prosthesis. In: Biocompatibility in Clinical Practice, Vol. II. (Ed.) D.F. Williams, CRC Press, Inc., Boca Raton, pp. 123-149, 1982.
Hoffer, J.A. and Loeb, G.E. Implantable Electrical and Mechanical Interfaces with Nerve and Muscle. Ann. Biomed. Eng., 8:351-360, 1980.
Chapin, J.K., Loeb, G.E. and Woodward, D.J. A simple technique for determination of footfall patterns of animals during treadmill locomotion. J. Neurosci. Meth., 2:97-102, 1980.
Bak, M.J. and Loeb, G.E. A Pulsed Integrator for EMG Analysis. Electroenceph. & Clin. Neurophysiol., 47:738-741, 1979.
Loeb, G.E., Marks, W.B. and Beatty, P.G. Analysis and microelectronic design of tubular electrode arrays for chronic, multiple single unit recording from captured nerve fibers. Med. & Biol. Eng. & Comput., 15:195-201, 1977.
Loeb, G.E., Walker, A.E., Uematsu, S. and Konigsmark, B.W. Histological reaction to various conductive and dielectric films chronically implanted in the subdural space. J. Biomed. Mater. Res., 11:195-210, 1977.
Loeb, G.E., Bak, M.J. and Duysens, J. Long-term unit recording from somatosensory neurons in the spinal ganglia of the freely waling cat. Science, 197:1192-1194, 1977.
Loeb, G.E., Bak, M.J., Salcman, M. and Schmidt, E.M. Parylene as a Chronically Stable, Reproducible Microelectrode Insulator. IEEE-BME, 24:121-128, 1977.
Thomas, C.A., Jr., Springer, P.A., Loeb, G.E., Berwald-Netter, Y. and Okun, L.M. A Miniature Microelectrode Array to Monitor the Bioelectric Activity of Cultured Cells. Exp. Cell Res., 74:61-66, 1972.
|
|